0.05% CT PT Test Equipment Phase Angle Error Measurement

Zhengzhou Great Electric Co.,Ltd.
Contact Now

0.05% CT PT Test Equipment Phase Angle Error Measurement

Brand Name : HNMC

Model Number : HES-10

Place of Origin : China

MOQ : 1

Price : Negotiable

Payment Terms : T/T, L/C

Supply Ability : 10 set per month

Delivery Time : 30-45 days

Packaging Details : Wooden Package

Class : 0.05

Current Range : up to 3150A, or more (optional)

Voltage Range : up to 35KV

Operation mode : Automatically by PC software

Operating Range : 1%-120%

Rated Frequency : 50/60 HZ

Test bench rated capacity : 10KVA

Standard CT accuracy : 0.05% or better

Contact Now

0.05% Standard Bench Type CT PT Test Equipment Test Bench HES-10

System Configuration:

1) HES-10 CT&PT Test Bench

2) HES-1C Digital Transformer Tester

3) FY49 Current Transformer Burden (5A/1A optional)

4) HLS-30G2 Standard Current Transformer ( with Current Source)

5) FY95 Voltage Transformer Burden (100V,100/√3V or other ratio requirements are available)

6) HJS-35G2 Standard Voltage Transformer ( with Voltage Source)

7) Current Transformer Primary Testing Cable

8) CT & PT Secondary Testing Cable

9) PC Test software

Main Function

Ratio error and phase angle error test of CT & PT

Technical Parameter & Features

HES-10 CT&PT Test Bench

Input Voltage AC 220+/-10% 50HZ, Single Phase
Output voltage AC 0-250V
Rated Capacity 10KVA
Adjustment method Manual, coarse & fine adjustment
“Open-circuit demagnetization”, “Closed-circuit demagnetization”, “Error measurement”
Over current protection
Equipment Can be installation and placed: FY current transformer burden,FY voltage transformer burden,HES-1C Digital Transformer Tester,Other Control function etc

HES-1C Digital Transformer Tester

Rated current &voltage 5A, 1A, 110V, 110/√3V, 100/√3V, 100/3V etc
Measuring Range
Ratio error ±0.0001% ~ ±19.99%(three positions: 0.1999%, 1.999%, 19.99%). Minimum resolution:0.0001%.
Phase error ±0.01' ~ ±900'(three positions: 9.00',90.0',900'). Minimum resolution: 0.01'
Impedance 0.001Ω~ 19.99Ω. Minimum resolution: 0.001Ω
Admittance 0.001 ms ~ 19.99ms. Minimum resolution:0.001 ms
Power consumption < 20VA
Rated frequency 50 or 60HZ

HLS-30G2 Standard Current Transformer with current generator

Rated Primary Current (A) 5, 7.5, 10, 15, 20, 25, 30, 40, 50, 60, 75, 80, 100, 120, 150, 160, 200, 250,300, 315, 400, 500, 600, 630, 750, 800, 1000, 1200, 1250, 1500, 1600, 2000, 2500, 3000, 3150....or More (optional)
Rated Secondary Current 5A, 1A
Accuracy class 0.05% or higher
Rated secondary load 0.2 ohm
Frequency 50HZ
Operating Range 1% - 120%
Current source Capacity 10kVA or more


FY49 current transformer burden

Rated Current 5A or 1A (optional)
Operating Range 1%--120%
Rated load (VA)

CosФ = 0.8: 2.5, 3.75, 5, 6.25, 7.5, 10, 12.5, 15, 20, 25, 30, 40,

50, 60 VA or more options

CosФ = 1.0: 2.5, 3.75, 5, 6.25, 7.5, 10 VA or more options

Rate Frequency 50Hz
Accuracy Class ±3%

FY95 Voltage transformer burden

Rated voltage 100V, 100/√3V or more options
Operation Range 20%--120%
Rated load 1.25VA, 2.5VA, 5VA, 10VA,20VA, 40VA, 80VA (Total load:158.75 VA) or more option
Fundamental error ±3%
Power factor COSФ=0.8
Rated Frequency 50Hz

HJS-35G3 Standard Voltage Transformer with Voltage Generator

Rated primary voltage 6kV,10kV,15kV,22kV,35kV or more option
Rated secondary voltage 100V,100/√3V,110V,110/√3V, or more option
Accuracy class 0.05% or higher accuracy class
Secondary capacity 0.5VA or more option
Power factor cosΦ=1.0
Power frequency 50HZ
Range of operating voltage 20%--120%
Current transformer primary test cable

2000A x 3m x 1set,1000A x 5m x 1set

500A x 1.5m x 2set,250A x 1.5m x 2set,100A x 1.5m x 2set

CT PT secondary test cable Provided


Product Tags:

35KV 0.05% CT PT Test Equipment

      

35KV CT PT Test Equipment

      

60HZ 35KV instrument transformer test set

      